5-2
LY Installation and Maintenance for LY 1001, LY 2001 and LY 3001
LMAIM1501
Table 5.1 – Torque Drive Nut Custom Bore and Keyway Sizes
Unit Type
Maximum Bore
Maximum Keyway
and Size
inch (mm)
inch (mm)
LY 1001
1
¹₈
dia (28 dia)
¹₄
x
¹₈
(6 x 3)
LY 2001/3001
2
³₈
dia (60 dia)
⁵₈
x
⁵₁₆
(15 x 7.5)
NOTE: Before keywaying, match the Torque Nut with the Valve Stem to ensure proper keyway location. Use the
Keyway Index Mark (LY 1001 only) for locating appropriate keyway location.
Figure 5.2 – LY Keyway Locations
5.3
Installation Overview
CAUTION: Be sure to complete each step of the installation overview before electrically operating your
actuator. If the actuator is already mounted to a valve from the manufacturer, verify that the actuator is
mounted according to the following overview. Failure to follow the installation procedures could result in
personal injury and/or improper operation and could cause damage to the equipment.
1.
Mount Torque Nut (piece #32) in the actuator as shown in Figure 5.3 with the following alignment:
A.
For LY 1001 – Stop Lugs facing the Actuator Mounting Adapter with index lines positioned to face the
Mechanical Stop Screws.
B.
For LY 2001/3001 – Torque Nut axially aligned on the Drive Sleeve so that the bottom of the nut is
positioned inside the Actuator Mounting Base.
A
B
C
D
LY 1001 Keyway
Location Marks
D
A
B
C
Torque Nut
Stop Lug
LY 2001/3001 Keyway
Location Positions
Flow Control Division
Limitorque Actuation Systems