Default = 0 (min. = -268 435 456, max. = 268 435 456)
NOTE
We suggest activating the preset when the actuator is in stop. See the
WARNING
A new value has to be set in the
Distance per revolution [0x00]
value is changed. After having entered a new
value in
it is not necessary to set new values for travel
limits as the Preset function calculates them automatically and initializes again
the positive and negative limits according to the values set in the
explanation see on page 45.
Jog step length [0x14]
[Register 21, Unsigned16, rw]
If the incremental jog function is enabled (bit 4
= 1), the activation of the bits
step toward the positive or negative direction having the length, expressed in
pulses, set next to this item to be executed at rising edge; then the actuator
stops and waits for another command.
Default = 1000 (min. = 1, max. = 10000).
Extra commands register [0x29]
[Register 42, Unsigned16, rw]
Byte structure of the
Extra commands register [0x29]
byte
MSB
LSB
bit
15
…
8
7
…
0
msb
lsb
msb
lsb
Byte 0
bit 0:
Not used.
Control by PC
bit 1:
This function is reserved only for use and service of Lika
Electronic engineers (only used with Modbus service port).
bits 2 … 7
Not used.
MAN RD6 MB E 1.1
Programming parameters
69 of 92
RD6 Modbus®