Target not valid
bit 5
The set target position is over the maximum travel limits.
Emergency
bit 6
Bit 7
to low value (0); or alarms are active in the unit.
Overcurrent
bit 7
Motor overcurrent.
Byte 1
Electronics Overtemperature
bit 8
The temperature of the MOSFETs detected by an internal
probe is exceeding the maximum ratings (see
on page 79). Please wait some minutes for the
actuator to cool down. Ensure that the operating
temperature is within the range.
Motor Overtemperature
bit 9
The temperature of the motor detected by an internal probe
is exceeding the maximum ratings (see
on page 79). Please wait some minutes for the
actuator to cool down. Ensure that the operating
temperature is within the range.
Undervoltage
bit 10
The power supply voltage is under the minimum ratings
allowed. Please ensure that the power supply voltage is
within the range.
Watch dog
bit 11
When the Watch dog function is enabled (bit 8
in
is set to “=1”), if the device
does not receive a message from the Server within 1 second,
the system forces an alarm condition (the
alarm
bit is activated). The alarm is invoked to appear as soon as
the Modbus network communication is restored. The Watch
dog function is a safety timer that uses a time-out to detect
loop or deadlock conditions. For instance, should the serial
communication be cut off while a command is still active
and running -a jog command for example- the Watch dog
safety system immediately takes action and commands a
safety stop of the device; furthermore an alarm is triggered.
bits 12 and 13
Not used.
MAN RD6 MB E 1.1
Programming parameters
76 of 92