5.4 “Parameter” page
By pressing the
PARAMETER
button in the sidebar menu the operator enters
the
Parameter
page.
In this page the list of the parameters available to set the RD6-Modbus
positioning units (machine data) is displayed. On the left of each field the values
currently loaded in the unit are shown; while the minimum and maximum
values allowed are shown on the right. For detailed information on the function
and the setting of each parameter refer to the “8.1.1 Holding Register
parameters” section on page 63.
To enter a new value type it in the blank field and then press the
ENTER
key in
the keyboard. If you set a value that is not allowed (out of range), at
confirmation prompt the field is highlighted in red and the RD6 unit is forced in
alarm condition (the
status bit is activated and the
error messages are invoked to appear). Enter a valid
value and then press the
RESET ALARM
button in the
Operative mode
page to
restore the normal work condition of the device.
To save the entered values on the non-volatile memory of the device press the
SAVE PARAMETER
button. If the power is turned off before saving the values
all data not saved will be lost! For any further information on saving the
parameters refer to the
MAN RD6 MB E 1.1
Quick reference
33 of 92
RD6 Modbus®