![Lika RD6 Series User Manual Download Page 31](http://html.mh-extra.com/html/lika/rd6-series/rd6-series_user-manual_1915979031.webp)
If the
INFINITE LOOP
check box is not selected, when you press the
START
button, the device starts running in order to reach the first commanded
position; as soon as the commanded position is reached, the device stops and
waits for the set interval to expire; you must then press the
START
button again
to command the unit to reach the second position; and so on.
The movement (step) that the actuator is currently performing is shown next to
the
CURRENT STEP
item. The interval between a movement and the following
one is shown next to the
WAIT
item.
It is possible to save a work program you created. To do so press the
SAVE
PROGR.
button. Once you press the button the
Save as
dialog box appears on
the screen: the operator must type the .prg file name and specify the path
where the file has to be located. When you press the
SAVE
button to confirm,
the dialog box closes. Set values are saved automatically.
To load a previously saved work program, press the
LOAD PROGR.
button. Once
you press the button, the
Open
dialog box appears on the screen: the operator
must open the folder where the previously saved .prg file is located, then select
it and finally confirm the choice by pressing the
OPEN
button, the dialog box
closes and the work values are automatically loaded.
RESET PRG.
button zero-sets the counter meant to detect the steps in the
execution of the running program: when the operator presses the
START
button
the device will start running from step 1, i.e. in order to reach the first
commanded position, whatever the position reached previously.
To disable the execution of a work program deselect the
ENABLE PROGRAM
check box.
In the box just below the
RD6-MB
box the following functions are available.
Position error [pulses]
Position following error [0x05-0x06]
Speed [rpm]
Electronics temperature [°C]
MAN RD6 MB E 1.1
Quick reference
31 of 92
RD6 Modbus®