SFA-5000 • SFA-10000 CANopen®
6500-00 Operating status
[Unsigned16, ro]
Bit
Function
bit = 0
bit = 1
0
Count up
information
rewinding the
wire
Count up
information
pulling the wire
out
1
not used
2
Disabled
Enabled
3 … 11
not used
12
Position >
Position <
13
Position <
Position >
14
not used
15
Stopped
/
Pre-operational
Operational
Code sequence
It shows the value that is currently set through the bit 0
object. If the bit is “=0” the output encoder
position value has been set to increase when you rewind the wire; if the bit is
“=1” instead the output encoder position value has been set to increase when
you pull the wire out. To set the code sequence you must set the bit 0
information on setting and using the counting direction function refer to the
Scaling function
It shows the value that is currently set through the bit 2
object. In other words, it is intended to
show whether the scaling function is enabled or disabled. If the value is “=0” the
scaling function is disabled; if the value is “=1” instead the scaling function is
enabled. To disable / enable the scaling function you must set the bit 2
further information on setting and using the scaling function refer to the
Limit switch min.
If the encoder position is greater than the value set in the
object, the bit 12 of this object is set to “0”.
MAN SFA_5000_10000_CB E 1.0.odt
6 - CANopen® interface
70 of 88