![LI-COR LI7200RS Instruction Manual Download Page 90](http://html.mh-extra.com/html/li-cor/li7200rs/li7200rs_instruction-manual_1906669090.webp)
Section 3. Operation
After configuring the transfer and selecting files, click
Start
.
You can also use third-party file transfer (SFTP) applications to transfer data, such
as WinSCP. In this case, connect using the instrument IP address and the fol-
lowing settings:
l
Port:
22
or
2200
if you have forwarded port 22 to port 2200.
l
Username:
licor
l
Password:
licor
You will see all of the files in the file system. The files of interest are in a
data
folder.
EddyPro Processing Modes on the SmartFlux
System
When using the SmartFlux System or SmartFlux 2 System with express settings,
simply enter site information and configuring your sensors. But when site con-
ditions or objectives require advanced settings, you will use EddyPro
®
to create a
SmartFlux advanced configuration file. In this section, we describe how to use
Express and Advanced processing modes.
Express Processing
EddyPro Express mode is the default configuration for the flux computation in the
SmartFlux System or SmartFlux 2 System. Express settings are loaded automatically
unless you specify an EddyPro Advanced configuration file. In most cases, EddyPro
Express provides final, fully corrected and valid fluxes that can be directly used for
further analysis. In a few special cases, however, Express fluxes may not be fully
accurate and only serve a diagnostic purpose.
Advanced Processing
Advanced Mode provides you with the high-level capabilities of the EddyPro
Advanced, computing fully corrected flux results in real-time with the processing
options of your choice.
The SmartFlux configuration file, needed to run EddyPro in Advanced mode inside
the original SmartFlux or SmartFlux 2 System, is created in EddyPro 5 or higher.
3-48
LI-7200RS Enclosed CO₂/H₂O Analyzer
Summary of Contents for LI7200RS
Page 1: ...Enclosed CO2 H2O Gas Analyzer Instruction Manual...
Page 2: ......
Page 11: ...ix Appendix C Suppliers Appendix D Configuration Grammar Appendix E Warranty Appendix F Index...
Page 12: ...x...
Page 20: ...Section 1 General Information 1 8 LI 7200RS Enclosed CO H O Analyzer...
Page 54: ...Section 3 Operation 3 12 LI 7200RS Enclosed CO H O Analyzer...
Page 112: ...Section 4 User Calibration 4 12 LI 7200RS Enclosed CO H O Analyzer...
Page 130: ...Section 5 Maintenance 5 18 LI 7200RS Enclosed CO H O Analyzer...
Page 138: ...Section 6 Troubleshooting 6 8 LI 7200RS Enclosed CO H O Analyzer...
Page 184: ...Section 8 Theory of Operation 8 12 LI 7200RS Enclosed CO H O Analyzer...
Page 187: ...Gas Analyzer Dimensions Appendix A Specifications A 3 Appendix A Specifications...
Page 188: ...Appendix A Specifications LI 7550 Dimensions A 4 LI 7200RS Enclosed CO H O Analyzer...
Page 192: ...Appendix B Pin Assignments B 2 LI 7200RS Enclosed CO H O Analyzer...
Page 196: ...Appendix C Suppliers C 4 LI 7200RS Enclosed CO H O Analyzer...
Page 225: ......