L'HOTELLIER
COMPONENT MAINTENANCE MANUAL
12589-( )
PRINTED IN FRANCE
26-20-50
Page 7011
APR 01/11
G.
Apply The rust inhibitor to the burst disc on the fill-and-safety fitting as follows:
(1) Put the application tube approximately 1.00 inc (2.54cm) into the inner diameter of the
fill-and-safety fitting
(2) Press the actuating plunger two times
(3) Remove the application tube from the fill-and-safety fitting
H.
Visually examine the burst disc to make sure the rust inhibitor covers the entire surface of the
burs disc. If necessary apply the inhibitor again until the rust inhibitor fully covers the burst
disc.
I.
Install protection cap on the fill-and-safety fitting. Tighten the cap with your hand
Identification and Characteristics Label
Figure 7002/GRAPHIC 26-20-50-812-A01
Weighing Label
Figure 7003/GRAPHIC 26-20-50-813-A01