L'HOTELLIER
COMPONENT MAINTENANCE MANUAL
12589-( )
PRINTED IN FRANCE
26-20-50
Page 1001
APR 01/11
TESTING AND FAULT ISOLATION
TASK 26-20-50-700-801-A01
1. Testing
A. General
This section contains the procedures, materials, and equipment necessary to do the tests of the
container and to find the defective parts. Do the visual checks, leak tests and the necessary
repairs before you do the electrical and hydrostatic tests. See IPL Figure 1 for the location of the
parts on the container.
NOTE : During the maintenance operations, the container must be without cartridges.
TASK 26-20-50-940-801-A01
2.
Test Equipment and Materials
A.
Table 1001 gives a list of the test equipment and materials necessary to do tests of the fire
extinguisher container. Refer to SPECIAL TOOLS, FIXTURES, EQUIPMENT AND
CONSUMABLES section for the specifications and where to get the items. You can use
alternative equipment and materials if the measurement accuracy and material life is not
decreased. All calibrated equipment must have a current calibration approval.
NOTE : You can use equivalent alternatives for the items given in the table.
Table 1001
Test Equipment and Materials
DESCRIPTION
PART NUMBER OR SPECIFICATION
Recharge kit
751770
Reprocessing bench “Halon”
751741
Charging Adapter / Lock-pin Handle
71804 / 751913
Wrench adapter
751934
Leak Detector
BACHARACH H25 IR
Leak Standard Detector
1000 Bubbles
Hydrostatic Pressure Test Setup
OUT97131
Safety Proof Booth
751776
Pressure Test Plug, Fill Fitting
OUT70065
Pressure Test Plug, Switch Fitting
OUT70066
Seal washer “BS” for OUT70066 “BS” C18
10216
O-Ring for OUT 72370 / OUT72371 (Qty = 2)
10215
O-Ring for OUT70065
10217
Pressure Test Cap, Neck, Nipple adapter
OUT72371
Pressure Test Cap, Neck obturator
OUT72370
The document reference is online, please check the correspondence between the online documentation and the printed version.