35
206-4310
Installer Menu (Cont.)
000 - INSTALLER SEQUENCE
Specifies entry sequence to the Installer Menu.
0 = 9876
1 = 4321
2 = 1478
3 = 3698
001 - POWER MANAGE (Power Management)
Energy saving feature. Determines the number of hours, in the
range 1 to 7, of inactivity allowed, either at the display control
panel or from the remote, before the STB automatically turns itself
OFF. If set to 0, Power Management is disabled.
002 - AC ON (AC Power Switchable)
Set to 0 (default) for standard STB/display turn ON/OFF operation.
If set to 1, this allows the STB/display panel to turn ON when AC
power is applied. Pressing the POWER button is not necessary.
This is desirable if the STB is plugged into a switched AC outlet.
Though note that if the Pro:Centric application is loaded (i.e., item
98 PRO:CENTRIC is not set to 0), the STB will reboot and initiate
an update event once every 24 hours. During the update event,
the STB checks for and downloads any available updates from the
Pro:Centric server (item 119 DATA CHANNEL set from 1 to 135 or
253). The time at which this event occurs depends on the setting of
item 121 UPDATE TIME HR. See item 119 and 121 descriptions
for further information. Once the update cycle is complete, the
STB completes the reboot and resumes its ON state.
Note:
If set to 1, the STB does not respond to ON/OFF commands
from the remote, and the SLEEP TIMER is also nonfunctional.
Set to 2 or 3 to enable the Instant ON feature (see additional
information below).
The Instant ON feature allows the STB to turn ON when AC power
is applied, while the display panel remains OFF. The STB retains
its ON status, and the POWER button only toggles the display On
and Off.
•
If this item is set to 2, the STB will reboot and, if applicable (i.e.,
item 119 set from 1 to 135 or 253), check for and download any
available updates from the Pro:Centric server each time the
display panel is turned OFF. This setting is not recommended if
the STB will be configured with a resident application.
•
If this item is set to 3, the STB will not reboot to check for and
download updates each time the display panel is turned OFF,
with the following exception: the first time the display is turned
OFF after this item is set to 3, the STB will reboot and initiate an
update event (Data Channel Auto Search and/or check for and
download of updates—see also paragraph below). This setting
is recommended if the STB will be configured with a resident
application. In this mode, the standard check for and download
of updates is under application control. Refer to your site-specific
documentation for further information on configuring the STB with
a resident application.
When this item is set to 2 or 3, the STB also will reboot and initiate
an update event once every 24 hours. During the update event, the
STB, as applicable, performs a Data Channel Auto Search (item
119 set to 255) and/or checks for and downloads any available
updates from the Pro:Centric server (item 119 set from 1 to 135 or
253). The time at which this event occurs depends on the setting of
item 121. See item 119 and 121 descriptions for further information.
Once the update cycle is complete, the STB completes the reboot
and resumes its ON state with the display panel OFF.
003 - BAND/AFC (Band/Automatic Frequency Control)
There are four possible settings for this option:
0 = Broadcast
1 = CATV (default)
2 = HRC
3 = IRC
If some channels were not found by Auto Tuning (Channel
Search), select the appropriate Band setting here, and add the
channels using the Channel Edit option in the Channel Menu.
004 - STRT CHANNEL (Start Channel)
If active, this function allows you to determine the initial Major
Start Channel number when the STB/display panel is turned
ON. This feature is useful for an in-house information channel,
since the STB/display would always select that channel when it is
turned ON. If set to 255, the last channel tuned before the STB/
display was turned OFF will be the channel tuned when the STB/
display is turned ON again.
Note:
For a digital Start Channel, always remember to set item
104 to the Minor Start Channel number.
Detailed Descriptions of Installer Menu Items
Installer Menu Items 117 through 122
Item
Function
Value Range
Default Value
Brief Description of Function
117
FACT DEFAULT
0 / 1
0
Set to 1 to restore the factory default settings of all Installer Menu items.
119
DATA CHANNEL
0 – 135, 253,
255
255
Set to 0 to disable. Set from 1 to 135 to match the RF channel number used by
the Pro:Centric server as its data channel. Set to 255 to use Auto Search to
find the Pro:Centric RF channel. (See detailed descriptions.)
121
UPDATE TIME HR
0 – 23, 128
128
Sets the Wake For Update hour. The value “128” is displayed as “OFF.” Directly
entering 128 turns the Wake For Update feature OFF.
122
UPDATE TIME MN
0 – 59, 255
0
Sets the minute for Wake For Update. (See detailed descriptions.)