FAILURE MODE FLOW CHART
Note :
Just after self-clean start, the door lock motor
starts to rotate.
During that time if the door lock switch does
not operate properly after rotating twice, then
supervising circuit detects a Door Lock failure
and the F-10 error code appears.
Door Lock System Failure,F-10?
Replace the Relay PCB(EBR52349701)
Is the disconnect or loose
connector?
1. Between Main PCB and
Relay PCB (CN7,CN10)
2.Electric wiring of relay PCB(CN12)
3.Electric wiring of Locking Motor and Micro Switch
4.Electric wiring of CN4 of Main PCB
Yes
Reconnect
or repair
the connector
1
CN12
CN7
CN4
Power Off
Yes
Yes
Is the door lock switch
(micro switch) normal?
measure the resistance of
door lock switch
normally open type
Yes
Replace the
micro switch
2
Power Off
Yes
Normal Abnormal
Is the resistance of the locking
motor normal ?
measure the resistance of
locking motor
Normal : approximately 2.6
㏀
Abnormal : infinite or below 5
Ω
No
Replace the
locking motor
3
Power Off