6-14
FAILURE MODE FLOW CHART
F-3 error (Touch-sensor key
error)
Or Key does not input
Is the disconnect or
loose connector?
Between CN1of Key PCB and
CN3 of Main PCB
Yes
Reconnect
or repair
the connector
1
Power Off
Yes
No
Yes
Is the wiring between CN1 and
CN3 nomal ?
Check the open/short test of
wire facing with each other
from 1pin to 14pin
No
Replace
or repair
the wire
2
11pin
11pin
Power Off
Is the Key PCB
normal operation?
Check:
Re-connect CN1 of Key PCB
and CN3 of Main PCB
Using the key test mode
To enter the test mode, follow these steps:
1. press the “clear” key
2. press the “BAKE”,”BROIL” key
at the same time
3. press the “BAKE”,”BROIL” key
at the same time again.
4. press the NUM “7” key
5 .Check the key refer to the next page
(appendix)
No
Replace
The Key PCB
(EBR60939401)
3
4
Power On
Replace the Main PCB(EBR52349505)
Yes