4-16
Triple surface unit:
Right Front(RF)
Element
1. Refer to page 3-7 for the servicing procedure
2. Set the Multiple meter scale to the R x 1
3. Disconnect wires from cook-top elements
4. Touch the ohmmeter test leads to the (E1 & 1A)
and (E2 & 1A) and (E3 & 1A)
The meter should indicate.
- (E3 & 1A)
70.5
Ω
± 10%
- (E2 & 1A)
50.0
Ω
± 10%
- (E1 & 1A)
49.5
Ω
± 10%
5. Touch the ohmmeter test leads to limiter
terminals 1A and 2A. The meter should indicate
continuity(0
Ω
)
6. Touch the ohmmeter test leads to limiter
terminals 1B and 2B.
With the temperature below 150 ˚F, the meter
should indicate an open circuit(infinite).
With the temperature above 150 ˚F, the meter
should indicate continuity (0
Ω
).
Components
Test procedures
Results
Normal: Approximately 70.5
Ω
Normal: Approximately 50
Ω
Normal: Approximately 49.5
Ω
Normal: continuity
(below 0.5
Ω
)
If not replace
Below 150˚F
open circuit(infinite).
Above 150˚F
continuity (0
Ω
)