4-13
Single surface units:
Left Rear (LR)
and
Right Rear(RR)
Element
1. Refer to page 3-7 for the servicing procedure
2. Set the Multiple meter scale to the R x 1
3. Disconnect wires from cook-top elements
4. Touch the ohmmeter test leads to the element
terminal and 1A.
The meter should indicate 46
Ω
± 10%
5. Touch the ohmmeter test leads to limiter
terminals 1A and 2A. The meter should indicate
continuity.(0
Ω
)
6. Touch the ohmmeter test leads to limiter
terminals 1B and 2B.
With the temperature below 150˚F, the meter
should indicate an open circuit(infinite).
With the temperature above 150˚F, the meter
should indicate continuity (0
Ω
).
Components
Test procedures
Results
Normal: Approximately 46
Ω
,
If not replace
Normal: continuity
(below 0.5
Ω
)
If not replace
Below 150˚F
open circuit(infinite).
Above 150˚F
continuity (0
Ω
)
Element
terminal
Element
terminal
1A
1A
2A
1B
2B