4-3
Oven Sensor
Door switch
Broil heater
1. Refer to page 3-15 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1000)
Components
Test procedures
Results
1. Refer to page 3-9 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1000)
Normal: Approximately
1.09 k
Ω
± 10%
If not replace
Door open
Door closed
Continuity
Infinite
NOTE: Oven sensor is so sensitive to temperature
Do test after cooling down sufficiently
NOTE:
Ω
Value was tested
at room temperature
(77F/25˚C)
1. Refer to page 3-10 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale : R x 1)
Normal: Approximately
14
Ω
± 10%
If not replace
NOTE:
Ω
Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.