– 54 –
WARNING:
Disconnect electrical power before servicing.
Caution
: Label all wires prior to disconnection. Wiring errors can cause improper and dangerous
operation. Verify operation after servicing.
Component Voltage Testing
Component
Test Locations
Conditions
Voltage
Convection
Non-
Convection
Oven Light
OL to N
P103-2 to P103-1
Door closed and oven light not
selected on from control panel
120 VAC
Door Open
0 VAC
Door closed and oven light
selected on from control panel
(relay clicks)
Bake Glow Bar
Bake to N
P102-2 to P103-1
Bake operation initiated (relay
clicks)
120 VAC
Bake operation not initiated or
burner in cycle off status
0 VAC
Broil Glow Bar
Broil to N
P102-1 to P103-1
Broil operation initiated (relay
clicks)
120 VAC
Broil operation not initiated or
burner in cycle off status
0 VAC
Warming Drawer Element WD OUT to N
P102-4 to P103-1
Warming drawer operation initiated
(relay clicks)
120 VAC
Warming drawer operation not
initiated or element in cycle off
status
0 VAC
Latch Motor
MDL to N
MDL to P103-1
Door closed and clean operation
initiated (relay clicks)
120 VAC for 10
seconds locks
door
Door closed and clean operation
cancelled (relay clicks)
120 VAC for
10 seconds
unlocks door
Door open and clean operation
initiated (relay clicks)
120 VAC until
alarm stops
operation (25
seconds) - then
0 VAC
Fan Motor Hi Speed
GAS F Fan Hi to N N/A
Door closed and convection bake
or broil initiated
120 VAC (0
VAC during
pre-heat)
Fan Motor LO Speed
GAS S Fan LO
to N
N/A
Door closed and convection bake
or broil initiated
120 VAC (0
VAC during
pre-heat)
Surface Ignitor Switches
Violet wire
(disconnected from
module) to N
Violet wire
(disconnected from
module) to P103-1
Rotate knob to LITE position
120 VAC