– 5 –
WARNING:
All ranges can tip causing injury. Install
anti-tip device packed with range. The anti-tip de-
vice should be attached to the wall.
Installation information is for reference only.
See the Installation Instructions shipped with
the product for complete details and before
attempting to install the range.
6"
MIN
30" MIN
18" MIN
0"
0"
*
*
MINIMUM DIMENSIONS BETWEEN
COOKTOP AND WALLS ABOVE COOKTOP.
Power Supply
This appliance must be supplied with proper
voltage and frequency, connected to an
individually grounded branch circuit, and
protected by a circuit breaker or time delay fuse
as noted on rating plate.
Wiring must conform to the National Electrical
Codes.
Grounding Specifications
Ground Path Resistance
0.10W
Max.
Insulation Resistance
250KW
Min.
Gas Supply
Your range is designed to operate at a pressure
of 5” of water column on natural gas or, if
designed for LP gas (propane or butane), 10” of
water column.
Make sure you are supplying your range with the
type of gas for which it is designed.
This range is convertible for use on natural or
propane gas. If you decide to use this range on
LP gas, conversion must be made by a qualified
LP installer before attempting to operate the
range on that gas.
For proper operation, the pressure of natural gas
supplied to the regulator must be between 5” and
13” of water column. For LP gas, the pressure
supplied must be between 10” and 13” of water
column.
When checking for proper operation of the
regulator, the inlet pressure must be at least 1”
greater than the operating (manifold) pressure as
given above.
The pressure regulator located at the inlet of the
range manifold must remain in the supply line
regardless of whether natural or LP gas is being
used.
Minimum Clearances
Anti-Tip Device
Installation Requirements
A flexible metal appliance connector used to
connect the range to the gas supply line should
have an I.D. of 1/2” and be 5 feet in length
for ease of installation. In Canada, flexible
connectors must be single wall metal connectors
no longer than 6 feet in length.
Check for proper operation by carefully tipping the
range forward.
Recommended
area for 120V
outlet and gas
pipe stub and
shut-off valve.
Recommended area
for through-the-floor
connection of pipe stub
and shut-off valve.
Recommended
Spacing to
Heat Sensitive
Surfaces.