![background image](http://html.mh-extra.com/html/lg/lrg30355sb-30in-gas-range/lrg30355sb-30in-gas-range_technical-service-manual_218344039.webp)
– 39 –
Range Top Components and Replacement
Ignitor Wire
Wire Inlet
Inlet Tube
Bracket
5/8-in.
1/2-in.
(
Continued next page
)
Maintop Burner Assembly
WARNING:
Shut off gas to the range before
proceeding.
Each maintop burner assembly consists of the
burner cap, burner head, bracket, orifice, and
tube. To improve alignment and stability, the five
burner brackets have been mounted to the under
side of the cooktop using “T-15” Torx screws.
To remove the maintop burner assembly:
Remove the Maintop. (See
Maintop
.)
Note:
If removing the left front or left rear burner
assemblies, omit step 2.
Remove the two ¼-in. hex-head screws that
attach the shield to the top right side of the
manifold panel.
Pull the ignitor wire out of the wire inlet in the
bracket.
Using a
5
/
8
-in. socket and extension, remove
the nut that holds the bracket to the inlet tube
then lift the bracket off the tube.
Remove the ½-in. nut that holds the inlet tube
to the valve.
1.
2.
3.
4.
5.