- FTP: Mark up for sends recorded image to the
FTP server. You must have the FTP server for
using these options.
> Server Address: Enter the FTP server
address.
> Directory: Enter the FTP directory name to
save the received recorded images. If you
want to save in the root directory, enter [/].
> User ID: Enter the user ID for logging the
FTP server.
> Password: Enter the password for logging
the FTP server.
- E-mail: Mark up for sending an alarm notifica-
tion e-mail when alarm event occur. This option
may not activated depends on your environ-
ment of e-mail server. For more details ask your
network administrator and/or internet service
provider.
> Server Address: Enter the E-mail server
address.
> Sender Address: Enter the SMTP server
name or the IP address of the SMTP server.
> Receiver Address: Enter the E-mail receiver
address.
> Comments: Type the comments.
Note:
After change the options, you must click [Save] but-
ton in the option to confirm the settings.
DIO Setup
• Sensor
- Channel: Display the sensor number.
- Condition: Select the sensor condition.
> Enable: Select when you connect the exter-
nal sensor with the sensor input terminal of
the camera.
> Disable: Sensor function is not used.
- Type: Select the sensor type either Normally
Open or Normally Close.
- Name: You can set the sensor name. Enter the
sensor name.
Note:
If you set the [Condition] to [Enable], [Type]
to [Normally Close] and the sensor is not con-
nected, this may cause the malfunction of the
camera.
• Relay
- Channel: Display the relay number.
- Condition: Select [Enable] to control the exter-
nal relay. If you select [Disable], the Remote
Control, Local Control and Remote & Local
Control options are dimmed.
> Remote Control: You can control the relay
using the Web Viewer from external.
> Local Control: If the sensor input is occurred
or motion is detected, the relay is set to ON
in duration time and to Off after duration time
automatically.
Note:
The relay 1 is activated when motion detect-
ing or alarm of sensor 1 is occurred and
relay 2 is activated when alarm of sensor 2 is
occurred.
> Remote & Local Control: You can use the
Remote & Local control functions.
- Local Control Duration: You can set the dura-
tion time for local control function (0, 5, 10, 15,
20, 25, 30, 35, 40, 45, 50, 55 or 60 seconds)
- Name: You can set the relay name. Enter the
relay name using the alphabet characters and
numbers. You can not use the blank space.