4. Installation of outdoor unit
Installation of
Outdoor Units
SINGLE ZONE
300(11 13/16) or more
300(11-13/16)
or more
300(11 13/16) or more
600(23-19/32)
or more
500(19-11/16) or more
500(19-11/16) or more
500(19-11/16) or less
300(11 13/16) or more
500(19-11/16) or less
1000(39-3/8) or more
300(11-13/16) or more
500(19-11/16) or less
300(11 13/16) or more
1000(39-3/8) or more
600(23-19/32)
or more
1000(39-3/8) or more
300(11 13/16) or more
500(19-11/16) or more
300(11 13/16) or more
A
500(19-11/16) or less
L
H
1000(39-3/8) or more
Clearance of side discharge unit [Unit:mm(inch)]
1) Where there is an obstacle on the air intake side:
n
No obstacle above
• Obstacle on the suction side only
• Obstacle on the both sides
n
Obstacle above, too
• Obstacle on the air intake side, too
• Obstacle on the air intake side, and both sides
2) Where there is an obstacle on the discharge side:
n
No obstacle above
n
Obstacle above, too
3) Where there are obstacles on both suction and discharge sides:
n
Where the obstacles on the discharge side is higher than the unit:
• No obstacle above
• Obstacle above, too
The relations between H, A and L are as follows:
Close the bottom of the installation frame to prevent
the discharged air from being bypassed.
L A[mm(inch)]
0 < L ≤ 1/2H 750(29 1/32)
1/2H < L 1 000(39 3/8)
H < L
Set the stand as: L ≤ H
L ≤ H