43
users) he might want to have full LED intensity during the maintenance period. Therefore
it is possible to specify set the LEDs at full intensity for a specific period of time.
Maintenance time is the number of seconds that the LEDs are set to full intensity after a
port changes link state.
PARAMETERS
These parameters are displayed:
LED Intensity Timers
◆
Time
–
Time at which LED intensity is set.
◆
Intensity
–
LED intensity (Range: 0-100%, in increments of 10%, where 0% means off
and 100% means full power)
Maintenance
◆
On time at link change
–
LEDs set at full intensity for a specified period when a link
change occurs. (Default: 10 seconds)
◆
On at errors
–
LEDs set at full intensity when a link error occurs.
WEB INTERFACE
To configure LED intensity:
1. Click Configuration, Power Reduction, LED.
2. Set LED intensity for any required hour of the day. Click Add Time to set additional entries.
3. Set the duration of full intensity when a link change occurs.
4. Specify whether or not to use full intensity when a link error occurs.
5. Click Apply.
Reducing Power for EEE
Use the EEE Configuration page to configure Energy Efficient Ethernet (EEE) for specified
queues, and to specify urgent queues which are to transmit data after maximum latency
expires regardless of queue length.
PATH
Configuration \ Power Reduction \ EEE
Summary of Contents for GEP-1070
Page 80: ...80 authentication from any point within the network...
Page 168: ...168...