Starting up the device - Basic configuration
Leuze electronic
CML 730-PS
62
Figure 8.7: Display after successful teach
The next configuration step is to check the alignment.
8.3
Check alignment
Prerequisites:
• The light curtain must first be correctly aligned and a teach must be performed.
Check whether the green LEDs on the receiver control panel and transmitter illuminate continuously.
Use the bar graph indicator to check whether the light curtain is optimally aligned, i.e., whether the max
-
imum is reached for both the first beam (FB) and the last beam (LB) in the bar graph indicator.
Use the bar graph indicator to check the optimum alignment of the light curtain if you have corrected an
error that occurred.
The next configuration steps:
• Perform extended configurations on the receiver control panel if necessary (see chapter 8.5)
• Start up CML 700i light curtains with analog output (see chapter 9)
• Start up CML 700i light curtains with IO-Link interface (see chapter 10)
8.4
Setting the function reserve
The function reserve can be set to the following levels:
• High: High function reserve for stable operation, low sensitivity
• Medium: Medium function reserve
• Low: Low function reserve, high sensitivity
• Transparent: Detection of transparent objects
• Target function reserve: Automatic adjustment of the transmitter power and the receiving sensitivity
• Tx/Rx power: Manual, separate adjustment of the transmitter power and the receiving sensitivity
The function reserve can be set via the receiver control panel, via the IO-Link interface (see chapter 10)
or via the
Sensor Studio
configuration software (see chapter 12).
The structure of the configuration in the receiver control panel menu is as follows:
The sensitivity levels (e.g., high function reserve for stable operation, medium function reserve
and low function reserve) are configured ex works with “high function reserve for stable
operation”. The “low function reserve” configuration enables the detection of partially transparent
objects.
The switching threshold can be set for optimum operation for the detection of transparent objects
in the “Transparent” configuration.