11.3.1 Configuration of hole recognition via IO-Link interface
For hole recognition for web material map hole indication to output pin 2.
11.4 Example configuration - Activating and deactivating blanking areas
11.4.1 Configuration of blanking areas (general)
Perform the following settings to activate or deactivate blanking areas.
Example: automatic blanking of two areas during teaching
Example: Deactivation/resetting of auto blanking
11.4.2 Configuration of blanking areas via IO-Link interface
Perform blanking area activation and deactivation.
Example: automatic blanking of two areas during teaching
In the background, the values of objects INDEX 76 sub-index 3 et seq. are calculated and stored in non-
volatile memory. Upon successful teach completion, all other objects of index 76 are stored in non-volatile
memory if index 79, sub-index 2 is set to value 0 = non-volatile storage of teach values.
Example: Deactivation/resetting of auto blanking
Configuration of area 01
(group 14)
Index 00, bit offset 104:
= 1
Area 01 active
Index 100, bit offset 96:
= 0
Light switching
Index 100, bit offset 80:
= 65534
Start beam of the area dynamic: on 65534 (start beam = FIB)
Index 100, bit offset 64:
= 65532
End beam of the area dynamic: on 65532 (start beam = LIB)
Index 100, bit offset 48:
= 1
Number of active beams for area ON
Index 100, bit offset 32:
= 0
Number of active beams for area OFF
Digital IO Pin 2 Settings
(group 10)
Index 80, bit offset 24:
= 0
Pin 2 as output
Index 80, bit offset 16:
= 1
Switching behavior inverted
Index 80, bit offset 0:
= 1
Switching output area 32 … 1
Index 84, bit offset 0:
= 1
Bit mapping of area 01 to pin 2
Blanking settings
Parameter
Number of auto blanking areas
:
= 2
Two blanking areas permitted
Parameter
Auto blanking (during teaching)
:
= 1
Automatic blanking-area configuration active
System commands
Parameter
Teach command
:
= 1
Execute teach command
Blanking settings
Parameter
Number of auto blanking areas
:
= 0
No blanking areas permitted
Parameter
Auto blanking (during teaching)
:
= 0
Automatic blanking area configuration not active
Blanking settings
Parameter
Function for blanking area/logical value
for blanking area 1
:
= 0
No beams blanked
Parameter Function for blanking area/logical value
for blanking area 2:
= 0
No beams blanked
System commands
Parameter
Teach command
:
= 1
Execute teach command
Blanking settings
(group 8)
Index 76, bit offset 200:
= 2
Two blanking areas permitted
Index 76, bit offset 192:
= 1
Automatic blanking-area configuration active
System commands
(group 1)
Index 2
= 162
Execute teach