Example configurations
Leuze electronic
CML 730-PS
94
11.6.2 Configuration of a cascading arrangement via IO-Link interface
CML700i frame arrangement for cascading with IO-Link interface wiring
1
Receiver
2
Transmitter
3
Interconnection cable 5 m (See table 0.20)
3
Interconnection cable 5 m (See table 0.12)
4
Connection cable 5 m (See table 17.3)
4
Connection cable 5 m (See table 0.13)
5
Interconnection cable 2 m (See table 0.22)
5
Interconnection cable 2 m (See table 0.12)
Configuring light curtain 1:
Configure the trigger settings (triggered, master, total cycle time).
Configure the digital IOs (pin 5) settings.
Configuring light curtain 2:
Configure the trigger settings (triggered, slave, delay time).
2
2
1
5
1
2
3
4
1
3
4
4
Cascading configuration
(group 7)
Index 73, bit offset 56
= 1
Cascading: active
Note: With cascading operation, the master must also be set to 1 (active)!
Index 73, bit offset 48
= 1
Function type: master - sends trigger signal
Index 73, bit offset 32
Master cycle time: total cycle time of all light curtains (LC1+LC2+LC3)
Duration of a TRIGGER cycle in ms
Digital IO1 (pin 5) settings
(group 10)
Index 81, bit offset 24
= 0
Pin 5 - input/output selection: output
Index 81, bit offset 16
= 0
Pin 5 - switching behavior: light switching
Index 81, bit offset 00
= 3
Pin 5 - output function: trigger output