Starting up the device - IO-Link interface
Leuze electronic
CML 730-PS
78
General configurations (group 4)
Additional settings (group 5)
Number of configured
logical individual beams
68
3
(bit
offset
= 32)
unsigned 16
RO
16
The number of logical individual beams is depen
-
dent on the selected operating mode.
The evaluation functions of the CML 700i are cal
-
culated on the basis of the logical individual
beams.
Number of cascades
68
4
(bit
offset
= 16)
unsigned 16
RO
1
The CML 700i has a modular structure. 8, 16 or
32 individual beams are always grouped into a
cascade.
Device cycle time
68
5
(bit
offset
= 0)
unsigned 16
RO
1000
The device cycle time defines the duration of a
measurement cycle of the CML 700i.
Parameter
Index
Sub-
index
Data type
Access
Value range
Default Explanation
Configured under group 4 “General configurations” are the type of scanning (parallel-/diagonal-
/crossed-beam), counting direction and minimum object diameter for the evaluation (smoothing).
The minimum hole size for the evaluation, e.g., with web material, is configured via inverted
smoothing.
Parameter
Index
Sub-
index
Data type
Access Value range
Default Explanation
Global settings
71
0
record 32 bit
RW
Beam mode
71
1
(bit
offset
= 24)
unsigned 8
RW
0 … 2
0
0: Parallel-beam scanning
1: Diagonal-beam scanning
2: Crossed-beam scanning
Counting direction
71
2
(bit
offset
= 16)
unsigned 8
RW
0 … 1
0
0: Normal - starting at the connector side
1: Inverted – starting opposite the connector site
Smoothing
71
3
(bit
offset
= 8)
unsigned 8
RW
1 … 255
1
Smoothing:
Less than i interrupted beams are ignored.
Inverted smoothing
71
4
(bit
offset
= 0)
unsigned 8
RW
1 … 255
1
Inverted smoothing:
Less than i free beams are ignored.
The additional settings specify the filter depth, integration time (hold function) and key lock on
the receiver control panel.
Parameter
Index
Sub-
index
Data type
Access Value range
Default Explanation
Additional settings
74
0
record 32 bit
RW
Teach mode
74
1
unsigned 8
RW
0
0
0: Automatic teach
Filter depth
74
2
(bit
offset
= 16)
unsigned 8
RW
1 … 255
1
The filter depth indicates the necessary number of
consistent beam states before the evaluation of
the measurement values. The filter depth corre
-
sponds to the number of passes with interrupted
beam so that the result leads to switching.