Technical data
Leuze electronic
CML 730-PS
114
16
Technical data
16.1 General specifications
Table 16.1:
Optical data
Table 16.2:
Measurement field data: Operating range limit and measurement field length of the
CML 730-PS
Table 16.3:
CML 730-PS operating ranges
Table 16.4:
CML 730-PS profile and measurement field lengths
Light source
LED (modulated light)
Wavelength
850 nm (infrared light)
Beam spacing [mm]
Typ. op. range limit
a)
[m]
Measurement field length
b)
[mm]
min.
max.
min.
max.
5
0.1
5.0
160
1280
a) Typ. operating range limit: min./max. attainable range without function reserve for parallel-beam scanning.
b) Measurement field lengths and beam spacings specified in fixed rasters, see ordering table.
Beam spacing [mm]
Operating range [m]
Parallel-beam
Operating range [m]
Diagonal-beam
Operating range [m]
Crossed-beam
min.
max.
min.
max.
min.
max.
5
0.1
4.0
0.2
3.0
0.2
2.5
NOTICE
Reduced operating range with sensitivity setting “Transparent”
If the sensitivity is set for the detection of transparent media, the operating range is reduced:
0.1 m … 1.75 m with beam spacing 5 mm and parallel-beam operation
Measurement field length B [mm]
Profile length L [mm]
with beam spacing A: 5 mm
160
168
240
248
320
328
400
408
480
488
560
568
640
648
720
728
800
808