Installation and mounting
18
AMS 300
i
Leuze electronic GmbH + Co. KG
If you have any questions concerning your shipment, please contact your supplier or your
local Leuze sales office.
Observe the applicable local regulations when disposing of the packaging materials.
5.2
Mounting the AMS 300
i
Figure 5.2: Mounting the device
The AMS 300
i
and the corresponding reflector are mounted on two mutually opposing, plane-
parallel, flat walls or system parts. For error-free position measurement, there must be an
unobstructed line-of-sight between the AMS 300
i
and the reflector.
Use M5 screws to fasten the laser measurement system. Secure the screws with a lock
washer to protect against loosening caused by vibrations.
A
M5 screw for align
-
ment
B
Knurled nut and nut
with WAF4 hexagon
socket for securing
C
Optical axis
A
B
A
C