Installation and mounting
Leuze electronic GmbH + Co. KG
AMS 300
i
23
TNT
35/7-2
4V
5.3
Mounting the AMS 300
i
with laser beam deflector unit
General information
The two available deflector units are used for the 90° deflection of the laser beam,
see "Accessories – Deflector unit" on page 62.
Attention!
The deflector units are designed for a maximum range of 40m.
Longer distances on request.
5.3.1
Mounting the laser beam deflector unit with integrated mounting bracket
The AMS 300
i
is screwed onto the mechanism of the US AMS 01 deflector unit. The mirror
can be mounted for three deflection directions:
1.
Upward beam deflection
2.
Beam deflection to the left
3.
Beam deflection to the right
The deflector unit is mounted on plane-parallel, flat walls or system parts. For error-free posi
-
tion measurement, there must be an unobstructed line-of-sight between the AMS 300
i
… and
the deflection mirror as well as between the mirror and the reflector.
Use the M5 screws to mount the deflector unit. Secure the screws with a lock washer to
protect against loosening caused by vibrations.
Figure 5.5: Mounting variants of the US AMS 01 laser beam deflector unit