Fast commissioning / operating principle
12
AMS 300
i
Leuze electronic GmbH + Co. KG
3.2
Connecting the voltage supply
The laser measurement system is connected using M12 connectors. The voltage supply is
connected via the PWR M12 connection.
Detailed information can be found in Chapter 7.
3.3
Display
Once the laser measurement system is supplied with voltage, the device status as well as
the measured position values can be read on the display. The display automatically switches
to the display of the measurement values.
Use the up/down buttons
to the left of the display to read and change a wide range
of data and parameters.
Depending on the connected interface, the network address or IP addresses must be config
-
ured via the display.
Detailed information can be found in Chapter 8.
3.4
AMS 300
i
on the RS 422/RS 232
The AMS 300
i
can transfer position values either via the RS 422 or via the RS 232. The two
interfaces cannot be active at the same time.
3.4.1
Data transfer via RS 422
The RS 422 interface is active by default.
The transmission parameters are listed in the menu structure and on the foldout at the end
of the technical description.
The parameters can be changed after activation of parameter enable.
Detailed information can be found in Chapter 8.3 and Chapter 9.4.4.
3.4.2
Data transfer via RS 232
Activating the RS 232 interface
• Activation of parameter enable
• Deactivation of the RS 422 interface – activation OFF
• Activation of the RS 232 interface – activation ON
• Deactivation of parameter enable
The RS 232 transfers the data with the preset parameters. They are listed in the menu struc
-
ture and on the foldout at the end of the technical description.
The parameters can be changed after activation of parameter enable.
Detailed information can be found in Chapter 8.3 and Chapter 9.4.4.