Technical data
14
AMS 300
i
Leuze electronic GmbH + Co. KG
The AMS 300
i
is designed in accordance with protection class III for supply
with PELV (protective extra-low voltage).
Mechanical data
Housing
Diecast zinc/aluminum
Optics
Glass
Weight
Approx. 2.45 kg
Degree of protection
IP 65 acc. to EN 60529
3)
Environmental conditions
Operating temperature
without device heating
with device heating
-5 °C … +50 °C
-
30°C … +50°C
4)
Storage temperature
-
30°C … +70°C
Air humidity
Max. 90% rel. humidity, non-condensing
MTTF
31 years (at 25 °C)
5)
Mechanical/electrical loading capacity
Vibration
Acc. to EN 60068
-
2
-
6
Noise
Acc. to EN 60060
-
2
-
64
Shock
Acc. to EN 60068
-
2
-
27
EMC
Acc. to EN 61000
-
6
-
2 and EN 61000
-
6
-
4
6)
1) Statistical error: 1 sigma; minimum switch-on time: 2min.
2) For UL applications: only for use in "Class 2" circuits according to NEC.
3) With screwed-on M12 plugs or mounted caps.
4) With devices with heating, the switch on/off area of the internal heating can be extended to prevent
condensation from forming. Total prevention of condensation cannot be guaranteed due to the limited
heating capacity of the AMS 300
i
.
5) We reserve the right to make changes. (Value is updated at regular intervals.)
6) This is a Class A product. In a domestic environment this product may cause radio interference, in which
case the operator may be required to take adequate measures.