1.3 Intended purpose
The measuring system is used for recording linear movements and processing the
measured data for a downstream control system with a CANopen Field Bus interface
according to ISO/DIS 11898.
The laser measuring device with CANopen protocol supports the device profile for
Encoder CiA Draft standard 406, version 2.0.
Particularly the measuring system is designed for the use of distance measurements
for the detection of the position and positioning of:
!
High-bay storage devices and lifting gears
!
Crane systems
!
Side-tracking skates and truck storage vehicles
!
Transfer machines
Warning
Switch off the voltage supply before carrying out wiring work or opening and
closing electrical connections!
Check all electrical connections before switching on the system!
Incorrectly wired connections can cause operating failures of the laser, while wrong
connections can lead to serious personal injuries and damage to property.
Mechanical or electrical modifications
to the measuring systems
are prohibited
for safety reasons!
In particular the following uses are forbidden
-
operation in areas where interruption of the laser beam, e.g. by covering the
laser lens opening, can lead to equipment damage or injury to personnel
-
in environments, in which strong rain, snow, fog, steams or direct insolations
etc. can influence the laser beam intensity negatively
-
operation in rooms with explosive atmospheres
-
operation for medical purposes
With use-purposes over 120m measuring length, a special reflector must to be
used!