Causes of Faults and Remedies
#Leuze
#Leuze electronic
GmbH + Co KG, Postfach 11 11, D-73277 Owen/Teck, In der Braike1, D-73277 Owen/Teck, Tel. ++49 (0)7021/5730, Fax ++49 (0)7021/573199
Page 38 of 42
LZ - ELE - BA - GB - 0009 - 00
Date: 01.07.2003
7 Causes of Faults and Remedies
The error causes are determined in "Object 1003h: ", S22. Depending on setting the
error messages must be acknowledged for resetting the error code (see chapter. "Object
1003h: ", S22 / "Object 2003 - Function external in", S28 and "Object 2004 - , S29").
Error code
Cause
Remedy
Bit 0
Intensity error
The device checks
the intensity of the
received laser signal
continuously, it was
detected a below-
minimum intensity.
1.
Clean measuring system optics
2.
Clean reflecting foil
3.
Rule out an interruption of the laser beam
If the possibility of soiling or interruption of the laser signal
can be ruled out, the device must be replaced.
Bit 1
Device temperature
The temperature has
exceeded or fallen
short of the range of
0 - 50°C at the
housing of the device
Appropriate measures must be taken to prevent the device
from overheating or undercooling.
Bit 2
Hardware error
The device has
detected an internal
hardware error.
If the error occurs repeated, the device must be replaced.
Bit 3
Laser diode
switched off
The bit is set, if the
laser diode was
switched off over the
bus, or the switching
input.
Serves only for information purposes.
Bit 4
Intensity warning
The device deter-
mined an intensity of
< 12%.
This message is only a warning and means that the
measuring system optics, or the reflecting foil is to be
cleaned. However, the device operates error-freely
furthermore.