Configuration / Parameter Setting
#Leuze
#Leuze electronic
GmbH + Co KG, Postfach 11 11, D-73277 Owen/Teck, In der Braike1, D-73277 Owen/Teck, Tel. ++49 (0)7021/5730, Fax ++49 (0)7021/573199
Page 30 of 42
LZ - ELE - BA - GB - 0009 - 00
Date: 01.07.2003
4.1.1.7 Object 6000h - Operating parameters
The operating parameters contain the functions for code sequence.
Structure of parameter
Unsigned16, Read/Write
Bit
Function
Bit = 0
Bit = 1
0 Code
Sequence
increasing
decreasing
1 reserved
3 - 11 reserved
12-15 Manufacturer specific functions
Code sequence:
The code sequence defines whether increasing or decreasing position values are
output.
0
(default)
With increasing distance to the laser, values increasing
1
With increasing distance to the laser, values decreasing
4.1.1.8 Object 6003h – Preset Value
The Preset function can be used to adjust the laser to any position value within a
range of 0 to measuring length in increments.
The output position value is set to the parameter "Preset value" when writing to this
object. The call of "Object 1010h: Store Parameters" isn't necessary.
Structure of parameter
Unsigned32, Read/Write
Preset value
Byte 0
Byte 1
Byte 2
Byte 3
2
7
to 2
0
2
15
to 2
8
2
23
to 2
16
2
31
to 2
24
4.1.1.9 Object 6004h – Position value
The object 6004h "Position value" defines the output position value for the
communication objects 1800h and 1802h.
Structure of parameter
Unsigned32, Read
Position value
Byte 0
Byte 1
Byte 2
Byte 3
2
7
to 2
0
2
15
to 2
8
2
23
to 2
16
2
31
to 2
24