Commissioning / Installation
#Leuze
#Leuze electronic
GmbH + Co KG, Postfach 11 11, D-73277 Owen/Teck, In der Braike1, D-73277 Owen/Teck, Tel. ++49 (0)7021/5730, Fax ++49 (0)7021/573199
Page 24 of 42
LZ - ELE - BA - GB - 0009 - 00
Date: 01.07.2003
3.2.4.7 Object 1008h: Manufacturer Device Name
Contains the manufacturer device name (visible string) "OMS2".
3.2.4.8 Object 1009h: Manufacturer Hardware Version
Contains the manufacturer hardware version (visible string).
3.2.4.9 Object 100Ah: Manufacturer Software Version
Contains the manufacturer software version (visible string).
See also object 6507.
3.2.4.10 Object 100Bh: Node-ID
This object contains the Node-ID (device address).
The value is selected by 6 hardware switches and cannot be changed using SDO
services.
Unsigned32, Read
Node_ID
Byte 0
Byte 1
Byte 2
Byte 3
Node-ID reserved reserved reserved
Value range: 1 - 64.
The Node-ID is the selected hardware number by sw 1. That means:
all 6 switches off = 0, Node-ID = 1
switch bit 5 = on = 32, Node-ID = 33
3.2.4.11 Object 100Ch: Guard-Time
The objects of index 100CH and 100DH include the guard time in milli-seconds and
the life time factor. The life time factor multiplied with the guard time gives the live time
for the node guarding protocol.
Unsigned16, Read/Write
Guard-Time
Byte 0
Byte 1
2
7
to 2
0
2
15
to 2
8
Summary of Contents for OMS2/120 CAN