EtherCAT interface
Leuze electronic
AMS 338
i
79
TNT
35/7-2
4
V
9.7.7.3
Object 6500h display of operating status from object 6000
Bit 0 - Bit 2
not used
Bit 3: counting direction
0 = positive - the measurement value increases with increasing distance.
1 = negative - the measurement value decreases with increasing distance.
Bit 4 - Bit 15: reserve
9.7.7.4
Object 6501
h
Measurement step
The resolution set in object 2000
h
sub-index 03 is specified in multiples of 0.001μm (1nm)
in object 6501.
Example:
If the default resolution in object 2000
h
is set to 1mm, the resolution for object 6501 is
converted to value 1 000 000. (1 000 000 x 1/1 000 000 = 1)
Index
Sub-
index
Name
Data type
Access
Value range
Remark
(hex)
(hex)
Minimum
Maximum
Default
6500
--
Operating
parameters
u16
ro
--
--
--
see below
Index
Sub-
index
Name
Data type
Access
Value range
Remark
(hex)
(hex)
Minimum
Maximum
Default
6501
--
Measure-
ment steps
u32
ro
--
--
--
see below