EtherCAT interface
Leuze electronic
AMS 338
i
61
TNT
35/7-2
4
V
9.7.6.2
Object 2001
h
Static preset value
The static preset value is a parameter that is not changed after the handover of the system
to the end user. It is configured during commissioning and remains unchanged thereafter.
A preset value can be entered into the object. The preset value is activated with "preset
teach" and deactivated with "preset reset". After preset teach, the current position value is
offset against the configured preset value. After preset reset, the original measurement value
is displayed.
9.7.6.3
Object 2002
h
Dynamic preset value
The dynamic preset value can be adapted permanently via the control.
The dynamic preset value is activated with "preset teach" and deactivated with "preset
reset". After preset teach, the current position value is offset against the configured preset
value. After preset reset, the original measurement value is displayed.
Index
Sub-
index
Name
Data type
Access
Value range
Remark
(hex)
(hex)
Minimum
Maximum
Default
2001
01
Preset value
static
int 32
rw
-999999
999999
0
Preset value, in mm
or in/100 depend-
ing on the unit
selected
02
Preset
settings
u 8
rw
0
2
0
Value 1 =
preset teach
Value 2 =
preset reset
Index
Sub-
index
Name
Data type
Access
Value range
Remark
(hex)
(hex)
Minimum
Maximum
Default
2002
01
Preset value
static
int 32
rw
-999999
999999
0
Preset value, in mm
or in/100 depend-
ing on the unit
selected
02
Preset
settings
u 8
rw
0
2
0
Value 1 =
preset teach
Value 2 =
preset reset