![Leuze electronic AMS 338i Technical Description Download Page 14](http://html1.mh-extra.com/html/leuze-electronic/ams-338i/ams-338i_technical-description_1883970014.webp)
Fast commissioning / operating principle
Leuze electronic
AMS 338
i
11
TNT
35/7-2
4
V
3
Fast commissioning / operating principle
Notice!
Below, you will find a
short description for the initial commissioning
of the AMS 338
i
.
Detailed explanations for the listed points can be found throughout the handbook.
3.1
Mounting the AMS 338
i
The AMS 338
i
and the corresponding reflector are mounted on two mutually opposing,
plane-parallel, flat walls.
Figure 3.1:
Schematic illustration of mounting
Attention!
For error-free position measurement, there must be an unobstructed line-of-sight between
the
AMS 338
i
and the reflector.
3.1.1
Mounting the device
The laser is mounted using 4 screws (M5).
Alignment is performed using 2 adjustment screws. Adjust so that the laser light spot is posi-
tioned at the center of the reflector. The alignment is to be secured with the knurled nut and
locked with the M5 nut.
Further information can be found in chapter 5.2 and chapter 5.3.
3.1.2
Mounting the reflector
The reflector is mounted using 4 screws (M5). The reflector is angled using the spacer
sleeves included. Incline the reflector by approx. 1°.