![Leuze electronic AMS 338i Technical Description Download Page 25](http://html1.mh-extra.com/html/leuze-electronic/ams-338i/ams-338i_technical-description_1883970025.webp)
Installation and mounting
22
AMS 338
i
Leuze electronic
The reflectors are mounted stationary and in parallel on one plane.
Both AMS 338
i
move independently of one another at different or the same dis-
tances to the reflectors.
Measurement distance
up to 120m
: minimum parallel spacing
X
≥
600mm
Measurement distance
up to 200m
: minimum parallel spacing
X
≥
750mm
Measurement distance
up to 300m
: minimum parallel spacing
X
≥
750mm
Notice!
Please note that when the AMS 338
i
are mounted in a mobile manner, travel tolerances could
cause the two laser light spots to move towards each other.
Take the travel tolerances of the vehicle into account when defining the parallel spacing of
adjacent AMS 338
i
.
5.2.3
Parallel mounting of AMS 338
i
and DDLS optical data transmission
The optical data transceivers of the DDLS series and the AMS 338
i
do not interfere with one
another. Depending on the size of the used reflector, the DDLS can be mounted with a
minimum parallel spacing of 100mm to the AMS 338
i
. The parallel spacing is independent
of the distance.