Frequency inverters
FMV 2107
FMV 2307
Display
On the operator panel :
- output frequency in Hz,
or
- output current as a % of the rated current In.
Status relay
240 V.A.C. relay - 6A (resistive load).
Activated when : the inverter is healthy or the frequency is higher than the minimum
frequency (P0).
Inverter status output
Open collector : 24V internal source, 100 mA.
Activated when : the inverter is running or the frequency is higher than the minimum
frequency.
Frequency :
- 0 to
±
10V, 5mA, precision
±
2 % : 0V = zero frequency, 10V = max. adjusted frequency.
analogue output
- 4 to 20 mA precision
±
2 % : 4 mA = zero frequency, 20 mA = max. adjusted frequency.
Motor load :
- 0 to
±
10V, 5 mA, precision
±
10 % for F > 15 Hz, 0V = zero current, 10V = 1.5 In
analogue output
- 4 to 20mA, precision
±
10 % for F > 15 Hz, 4mA = zero current, 20mA = 1.5 In.
Motor current reached
- 0V : current less than P5
logic output
- 10V : P5 reached
Diagnostic
The last 10 trip codes are stored.
Communication : PLC, PC, etc.
RS 485 and RS 422, protocol ANSI x 3.28 - 2.5 - A4.
RFI filter
- FMV 2107 : FN 350-8-29 and FN 350-20-29
- FMV 2307 : FN 351-8-29 and FN 351-16-29
Leakage current
SELF - MC 3.5T and 11T
attenuation chokes
Braking resistors
- FMV 2107 : R-FMV 140M and R-FMV 320M
(4 quadrants) R - FMV
- FMV 2307 : R-FMV 320T to R-FMV 2000T
Hoisting module
- FMV 2307 T : L - FMV *
Control and supervision
software
PEGASE
INDICATIONS
OPTIONS
SERIAL LINK