13.4 Error messages while programming on the
programming track
If an error occurred during programming or reading out process, you
will receive an error message:
Error 1
While programming or reading out a decoder, a power overload
(short circuit) was detected. The decoder may not be correctly
connected or may be defective.
Error 2
When programming or reading out a decoder, no decoder reaction
was detected. The decoder may not be
correctly connected to the
programming output of the LZ100/LZV100 command station (e. g. the
digital locomotive may not be properly placed on the programming
track).
Press the
key to delete the error message.
13.4.1 Display of other connected manual controls
While the command station is in programming mode, the displays of
the
other
manual controls shows a corresponding message.
I.e. another LH101 will display
in that situation.