2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in
place, clean, and correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. If the problem persists and there are no other DIMMs with the same indication, replace the DIMM.
•
FQXSPMA0013N: The System [ComputerSystemElementName] has detected no memory in the
system.
This message is for the use case when an implementation has detected that memory was detected in the
system.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Memory
SNMP Trap ID: 41
CIM Prefix: PLAT CIM ID: 0794
User Action:
Complete the following steps:
1. If the DIMM was disabled because of a memory fault, follow the procedure for that event.
2. If no memory fault is recorded in the logs, re-enable the DIMM through the Setup utility or the OneCLI
utility.
3. If problem persists, power cycle the server from the management console.
4. Reset XCC to default settings.
5. Reset UEFI to default settings.
6. Update XCC and UEFI firmware.
7. If problem persists, collect Service Data log.
8. Contact Lenovo Support.
•
FQXSPMA0022I: Memory sparing initiated for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
This message is for the use case when an implementation has detected that Memory double chip sparing
has been initiated.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0140
User Action:
Information only; no action is required.
•
FQXSPMA0024G: Sensor [SensorElementName] has asserted.
This message is for the use case when an implementation has detected a Sensor has asserted.
Severity: Warning
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - Memory
SNMP Trap ID: 43
57
Summary of Contents for ThinkSystem ST650 V2
Page 1: ...ThinkSystem ST650 V2 Messages and Codes Reference Machine Types 7Y45 and 7Y46 ...
Page 4: ...ii ThinkSystem ST650 V2 Messages and Codes Reference ...
Page 8: ...4 ThinkSystem ST650 V2 Messages and Codes Reference ...
Page 202: ...198 ThinkSystem ST650 V2 Messages and Codes Reference ...
Page 206: ...202 ThinkSystem ST650 V2 Messages and Codes Reference ...
Page 208: ...204 ThinkSystem ST650 V2 Messages and Codes Reference ...
Page 209: ......
Page 210: ......