FQXSPPW0104J: Non-redundant:Sufficient Resources from Redundancy Degraded or Fully
Redundant for [RedundancySetElementName] has asserted.
This message is for the use case when a Redundancy Set has transitioned from Redundancy Degraded or
Fully Redundant to Non-redundant:Sufficient.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Redundant Power Supply
SNMP Trap ID: 10
CIM Prefix: PLAT CIM ID: 0806
User Action:
Ensure the PSU wattage, PSU efficiency level, and the power supply unit is supported for the system.
•
FQXSPPW0110M: Non-redundant:Insufficient Resources for [RedundancySetElementName] has
asserted.
This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient
Resources.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Redundant Power Supply
SNMP Trap ID: 9
CIM Prefix: PLAT CIM ID: 0810
User Action:
Complete the following steps:
1. Check if any power adapter is missing, failing, or not installed properly. If so, re-install or replace it.
2. Check the power adapter max rate and power capping policy. If the required power resource is not
met, change the power adapter or modify the power capping mechanism.
•
FQXSPPW2001I: [PowerSupplyElementName] has been removed from container
[PhysicalPackageElementName].
This message is for the use case when an implementation has detected a Power Supply has been
removed.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0085
User Action:
Information only; no action is required.
•
FQXSPPW2002I: [PowerSupplyElementName] has returned to OK status.
This message is for the use case when an implementation has detected a Power Supply return to normal
operational status.
Severity: Info
Serviceable: No
97
Summary of Contents for ThinkSystem ST650 V2
Page 1: ...ThinkSystem ST650 V2 Messages and Codes Reference Machine Types 7Y45 and 7Y46 ...
Page 4: ...ii ThinkSystem ST650 V2 Messages and Codes Reference ...
Page 8: ...4 ThinkSystem ST650 V2 Messages and Codes Reference ...
Page 202: ...198 ThinkSystem ST650 V2 Messages and Codes Reference ...
Page 206: ...202 ThinkSystem ST650 V2 Messages and Codes Reference ...
Page 208: ...204 ThinkSystem ST650 V2 Messages and Codes Reference ...
Page 209: ......
Page 210: ......