Information only; no action is required.
•
FQXPMEM0005I: boot diagnostic program success
Severity: Info
User Action:
Information only; no action is required.
•
FQXPMEM0006M: Unable to locate diagnostic firmware image
Severity: Error
User Action:
1. Restart BMC via supported method and reboot the system.
2. Perform AC reset or virtual reseat.
Note:
When performing AC reset, after powering off AC, wait several seconds before powering on
AC. After AC power is restored, power on the host system.
3. If the problem persists, please contact technical support.
•
FQXPMEM0007M: Diagnostic image cannot be launched as "Console Redirection" is enabled
Severity: Error
User Action:
1. Disable “Configure Console Redirection” in UEFI Setup by following below steps: - Go to F1 Setup ->
System Settings -> Devices and I/O Ports-> Console Redirection Settings -> - Select "Console
Redirection" - Change the setting to “Disable” and save - Next reboot the system.
2. Perform AC reset or virtual reseat.
Note:
When performing AC reset, after powering off AC, wait several seconds before powering on
AC. After AC power is restored, power on the host system.
3. If the problem persists, please contact technical support.
•
FQXPMEM0008M: Diagnostic image cannot be launched as the image may be corrupt
Severity: Error
User Action:
1. Restart BMC via supported method and reboot the system.
2. Perform AC reset or virtual reseat.
Note:
When performing AC reset, after powering off AC, wait several seconds before powering on
AC. After AC power is restored, power on the host system.
3. Reflash the LXPM.
4. If the problem persists, please contact technical support.
•
FQXPMER0002I: Clearing RAID configuration and internal storage
Severity: Info
User Action:
Information only; no action is required.
•
FQXPMER0002M: Failed to clear RAID configuration
.
XClarity Provisioning Manager events
183
Summary of Contents for ThinkSystem ST650 V2
Page 1: ...ThinkSystem ST650 V2 Messages and Codes Reference Machine Types 7Y45 and 7Y46 ...
Page 4: ...ii ThinkSystem ST650 V2 Messages and Codes Reference ...
Page 8: ...4 ThinkSystem ST650 V2 Messages and Codes Reference ...
Page 202: ...198 ThinkSystem ST650 V2 Messages and Codes Reference ...
Page 206: ...202 ThinkSystem ST650 V2 Messages and Codes Reference ...
Page 208: ...204 ThinkSystem ST650 V2 Messages and Codes Reference ...
Page 209: ......
Page 210: ......