• 1100-watt platinum power supply
– Input power 115V or 230V ac
• 1600-watt platinum power supply
– Input power 115V or 230V ac
Before installing a hot-swap power supply:
1. Read the safety information and installation guidelines (see “Safety” on page iii and “Installation
2. Touch the static-protective package that contains the component to any unpainted metal surface on the
server; then, remove it from the package and place it on a static-protective surface.
3. If the server is in a rack, adjust the cable management arm (CMA) to gain access to the power supply
bay.
Figure 95. CMA adjustment
If you have installed the 2U CMA Upgrade Kit for Toolless Slide Rail or Toolless Slide Rail Kit with 2U
CMA, do the following:
a. Press down the stop bracket and rotate it to the open position.
b. Rotate the CMA out of the way to gain access to the power supply bay.
4.
Watch the procedure
. A video of this procedure is available from the following links:
• https://www.youtube.com/playlist?list=PLYV5R7hVcs-B2y7oAb54mfyuLrIusa_qE
• http://list.youku.com/albumlist/show/id_50483449
5. If the power supply unit to be installed comes with different wattage than the one that is already
installed, turn off the server and peripheral devices, and disconnect the power cords and all external
cables; then, remove the installed power supply unit (see “Remove a hot-swap power supply unit” on
page 93).
Important:
Do not mix power supplies with different wattages in the same server.
98
ThinkSystem SR850 Maintenance Manual
Summary of Contents for ThinkSystem SR850
Page 1: ...ThinkSystem SR850 Maintenance Manual Machine Type 7X18 and 7X19 ...
Page 8: ...vi ThinkSystem SR850 Maintenance Manual ...
Page 58: ...50 ThinkSystem SR850 Maintenance Manual ...
Page 142: ...134 ThinkSystem SR850 Maintenance Manual ...
Page 166: ...158 ThinkSystem SR850 Maintenance Manual ...
Page 170: ...162 ThinkSystem SR850 Maintenance Manual ...
Page 174: ...Taiwan BSMI RoHS declaration 166 ThinkSystem SR850 Maintenance Manual ...
Page 176: ...168 ThinkSystem SR850 Maintenance Manual ...
Page 182: ...174 ThinkSystem SR850 Maintenance Manual ...
Page 183: ......
Page 184: ...Part Number SP47A24295 Printed in China 1P P N SP47A24295 1PSP47A24295 ...