Figure 98. Removing a PHM
Attention:
To prevent damage to components, make sure that you follow the indicated loosening
sequence.
a. Fully loosen the Torx T30 captive fasteners on the processor-heat-sink module
in the removal
sequence shown
on the heat-sink label.
b. Lift the processor-heat-sink module from the processor socket.
After you remove a PHM:
• If you are removing the PHM as part of a system board replacement, set the PHM aside.
• If you are replacing the processor or heat sink, separate the processor and its retainer from the heat sink.