<s/n>
The serial number on the server. Type
sn zzzzzzz
, where
zzzzzzz
is the serial number.
<asset_method>
The server asset tag number. Type
asset aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
, where
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
is the asset tag number.
[access_method]
The access method that you select to use from the following methods:
• Online authenticated LAN access, type the command:
[−−bmc bmc_user_id:bmc_
password@bmc_internal_ip]
Where:
bmc_internal_ip
The BMC (Lenovo XClarity Controller) internal LAN/USB IP address. The default value is
169.254.95.118.
bmc_user_id
The BMC account (1 of 12 accounts). The default value is USERID.
bmc_password
The BMC account password (1 of 12 accounts). The default value is PASSW0RD (with a
zero 0 not an O).
Note:
If you do not specify any of these parameters, OneCLI will use the default values.
When the default values are used and OneCLI is unable to access the Lenovo XClarity
Controller using the online authenticated LAN access method, OneCLI will automatically
use the unauthenticated KCS access method.
Examples that do use the user ID and password default values:
onecli config set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model>
onecli config set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n>
onecli config set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag>
• Online KCS access (unauthenticated and user restricted): You do not need to specify a
value for
access_method
when you use this access method.
Note:
The KCS access method uses the IPMI/KCS interface, which requires that the IPMI
driver be installed.
The following commands are examples of not using the user ID and password default
values:
onecli config set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model>
onecli config set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n>
onecli config set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag>
• Remote LAN access, type the command:
Note:
When using the remote LAN access method to access Lenovo XClarity Controller
using the LAN from a client, the
host
and the
bmc_external_ip
address are required
parameters.
[−−bmc bmc_user_id:bmc_password@bmc_external_ip]
Where:
bmc_external_ip
The external BMC (Lenovo XClarity Controller) LAN IP address. There is no default
value. This parameter is required.
bmc_user_id
126
ThinkSystem SR850 Maintenance Manual
Summary of Contents for ThinkSystem SR850
Page 1: ...ThinkSystem SR850 Maintenance Manual Machine Type 7X18 and 7X19 ...
Page 8: ...vi ThinkSystem SR850 Maintenance Manual ...
Page 58: ...50 ThinkSystem SR850 Maintenance Manual ...
Page 142: ...134 ThinkSystem SR850 Maintenance Manual ...
Page 166: ...158 ThinkSystem SR850 Maintenance Manual ...
Page 170: ...162 ThinkSystem SR850 Maintenance Manual ...
Page 174: ...Taiwan BSMI RoHS declaration 166 ThinkSystem SR850 Maintenance Manual ...
Page 176: ...168 ThinkSystem SR850 Maintenance Manual ...
Page 182: ...174 ThinkSystem SR850 Maintenance Manual ...
Page 183: ......
Page 184: ...Part Number SP47A24295 Printed in China 1P P N SP47A24295 1PSP47A24295 ...