Server model: twenty 2.5-inch SAS/SATA drives, four 2.5-inch NVMe drives, one 24i RAID adapter
Figure 44. Cable routing for server models with twenty 2.5-inch SAS/SATA drives, four 2.5-inch NVMe drives, and one 24i
RAID adapter
Cable
From
To
1
Power cable for front backplane 1
Power connector on front backplane
1
Backplane power connector 1 on the
system board
2
SAS signal cable for front
backplane 1
SAS 0 and SAS 1 connectors on front
backplane 1
C0 and C1 connectors on the 24i
RAID adapter installed on riser 1
assembly
3
NVMe signal cable for front
backplane 1
NVMe 0, NVMe 1, NVMe 2, and
NVMe 3 connectors on front
backplane 1
NVMe 0–1 and NVMe 2–3 connectors
on the system board
4
Power cable for front backplane 2
Power connector on front backplane
2
Backplane power connector 2 on the
system board
5
SAS signal cable for front
backplane 2
SAS 0 and SAS 1 connectors on front
backplane 2
C2 and C3 connectors on the 24i
RAID adapter installed on riser 1
assembly
6
Power cable for front backplane 3
Power connector on front backplane
3
Backplane power connector 3 on the
system board
7
SAS signal cable for front
backplane 3
SAS 0 and SAS 1 connectors on front
backplane 3
C4 and C5 connectors on the 24i
RAID adapter installed on riser 1
assembly
.
63
Summary of Contents for ThinkSystem SR650
Page 1: ...ThinkSystem SR650 Maintenance Manual Machine Types 7X05 and 7X06 ...
Page 8: ...vi ThinkSystem SR650 Maintenance Manual ...
Page 20: ...12 ThinkSystem SR650 Maintenance Manual ...
Page 96: ...88 ThinkSystem SR650 Maintenance Manual ...
Page 154: ...Figure 107 Riser 1 assembly removal 146 ThinkSystem SR650 Maintenance Manual ...
Page 212: ...204 ThinkSystem SR650 Maintenance Manual ...
Page 230: ...222 ThinkSystem SR650 Maintenance Manual ...
Page 234: ...226 ThinkSystem SR650 Maintenance Manual ...
Page 243: ......
Page 244: ......