Server model: four 2.5-inch SAS/SATA drives, four 2.5-inch NVMe drives, the rear hot-swap drive
assembly, one 16i RAID adapter
Figure 25. Cable routing for server models with four 2.5-inch SAS/SATA drives, four 2.5-inch NVMe drives, the rear hot-
swap drive assembly, and one 16i RAID adapter
Cable
From
To
1
Power cable for front backplane
Power connector on front backplane
Backplane power connector 1 on the
system board
2
SAS signal cable for front
backplane
SAS 0 and SAS 1 connectors on front
backplane
C0 and C1 connectors on the 16i
RAID adapter installed on the RAID
adapter slot
3
NVMe signal cable for front
backplane
NVMe 0, NVMe 1, NVMe 2, and
NVMe 3 connectors on front
backplane
NVMe 0–1 and NVMe 2–3 connectors
on the system board
4
SAS signal cable for the rear hot-
swap drive assembly
Signal connector on the rear hot-
swap drive assembly
C2 connector on the 16i RAID
adapter installed on the RAID adapter
slot
.