© Copyright Lenovo 2018
Chapter 10: Spanning Tree Protocols
177
Port Priority
The
port
priority
helps
determine
which
bridge
port
becomes
the
root
port
or
the
designated
port.
The
case
for
the
root
port
is
when
two
switches
are
connected
using
a
minimum
of
two
links
with
the
same
path
‐
cost.
The
case
for
the
designated
port
is
in
a
network
topology
that
has
multiple
bridge
ports
with
the
same
path
‐
cost
connected
to
a
single
segment,
the
port
with
the
lowest
port
priority
becomes
the
designated
port
for
the
segment.
Use
the
following
commands
to
configure
the
port
priority:
where
priority
value
is
a
number
from
0
to
240,
in
increments
of
16
(such
as
0,
16,
32,
and
so
on).
If
the
specified
priority
value
is
not
evenly
divisible
by
16,
the
value
will
be
automatically
rounded
down
to
the
nearest
valid
increment
whenever
manually
changed
in
the
configuration.
Root Guard
The
root
guard
feature
provides
a
way
to
enforce
the
root
bridge
placement
in
the
network.
It
keeps
a
new
device
from
becoming
root
and
thereby
forcing
STP
re
‐
convergence.
If
a
root
‐
guard
enabled
port
detects
a
root
device,
that
port
will
be
placed
in
a
blocked
state.
You
can
configure
the
root
guard
at
the
port
level
using
the
following
commands:
The
default
state
is
none
(disabled).
Loop Guard
In
general,
STP
resolves
redundant
network
topologies
into
loop
‐
free
topologies.
The
loop
guard
feature
performs
additional
checking
to
detect
loops
that
might
not
be
found
using
Spanning
Tree.
STP
loop
guard
ensures
that
a
non
‐
designated
port
does
not
become
a
designated
port.
To
globally
enable
loop
guard,
enter
the
following
command:
Note:
The
global
loop
guard
command
will
be
effective
on
a
port
only
if
the
port
‐
level
loop
guard
command
is
set
to
default
as
shown
below:
NE2552E(config-if)# spanning-tree guard loop none
To
enable
loop
guard
at
the
port
level,
enter
the
following
command:
The
default
state
is
“none”,
i.e.
disabled.
NE2552E(config)#
interface port
<port>
NE2552E(config-if)#
spanning-tree stp
<STP
instance
or
range>
priority
<0
‐
240>
NE2552E(config)#
interface port
<port>
NE2552E(config-if)#
spanning-tree guard root
NE2552E(config)#
spanning-tree loopguard
NE2552E(config)#
interface port
<port>
NE2552E(config-if)#
spanning-tree guard loop
Summary of Contents for ThinkSystem NE2552E
Page 27: ... Copyright Lenovo 2018 27 Part 1 Getting Started ...
Page 28: ...28 NE2552E Application Guide for ENOS 8 4 ...
Page 70: ...70 NE2552E Application Guide for ENOS 8 4 ...
Page 85: ... Copyright Lenovo 2018 85 Part 2 Securing the Switch ...
Page 86: ...86 NE2552E Application Guide for ENOS 8 4 ...
Page 112: ...112 NE2552E Application Guide for ENOS 8 4 ...
Page 134: ...134 NE2552E Application Guide for ENOS 8 4 ...
Page 154: ...154 NE2552E Application Guide for ENOS 8 4 ...
Page 194: ...194 NE2552E Application Guide for ENOS 8 4 ...
Page 218: ...218 NE2552E Application Guide for ENOS 8 4 ...
Page 234: ...234 NE2552E Application Guide for ENOS 8 4 ...
Page 238: ...238 NE2552E Application Guide for ENOS 8 4 ...
Page 239: ... Copyright Lenovo 2018 239 Part 4 Advanced Switching Features ...
Page 240: ...240 NE2552E Application Guide for ENOS 8 4 ...
Page 242: ...242 NE2552E Application Guide for ENOS 8 4 ...
Page 278: ...278 NE2552E Application Guide for ENOS 8 4 ...
Page 284: ...284 NE2552E Application Guide for ENOS 8 4 ...
Page 314: ...314 NE2552E Application Guide for ENOS 8 4 ...
Page 338: ...338 NE2552E Application Guide for ENOS 8 4 ...
Page 374: ...374 NE2552E Application Guide for ENOS 8 4 ...
Page 388: ...388 NE2552E Application Guide for ENOS 8 4 ...
Page 418: ...418 NE2552E Application Guide for ENOS 8 4 ...
Page 430: ...430 NE2552E Application Guide for ENOS 8 4 ...
Page 432: ...432 NE2552E Application Guide for ENOS 8 4 ...
Page 436: ...436 NE2552E Application Guide for ENOS 8 4 ...
Page 460: ...460 NE2552E Application Guide for ENOS 8 4 ...
Page 461: ... Copyright Lenovo 2018 461 Part 7 Network Management ...
Page 462: ...462 NE2552E Application Guide for ENOS 8 4 ...
Page 476: ...476 NE2552E Application Guide for ENOS 8 4 ...
Page 498: ...498 NE2552E Application Guide for ENOS 8 4 ...
Page 520: ...520 NE2552E Application Guide for ENOS 8 4 ...
Page 534: ...534 NE2552E Application Guide for ENOS 8 4 ...
Page 536: ...536 NE2552E Application Guide for ENOS 8 4 ...
Page 544: ...544 NE2552E Application Guide for ENOS 8 4 ...
Page 549: ... Copyright Lenovo 2018 549 Part 9 Appendices ...
Page 550: ...550 NE2552E Application Guide for ENOS 8 4 ...
Page 566: ...566 NE2552E Application Guide for ENOS 8 4 ...
Page 572: ...572 NE2552E Application Guide for ENOS 8 4 ...
Page 573: ......
Page 574: ...Part Number 01KN246 Printed in USA IP P N 01KN246 ...