170
NE2552E Application Guide for ENOS 8.4
To
avoid
the
Actor
switch
ports
(with
the
same
admin
key)
from
aggregating
in
another
LAG,
you
can
configure
a
LAG
ID.
Ports
with
the
same
admin
key
(although
with
different
LAG
IDs)
compete
to
get
aggregated
in
a
LAG.
The
LAG
ID
for
the
LAG
is
decided
based
on
the
first
port
that
is
aggregated
in
the
LAG.
Ports
with
this
LAG
ID
get
aggregated
and
the
other
ports
are
placed
in
suspended
mode.
As
per
the
configuration
shown
in
,
if
port
38
gets
aggregated
first,
then
the
LAG
ID
of
port
38
would
be
the
LAG
ID
of
the
LAG.
Port
40
would
be
placed
in
suspended
mode.
When
in
suspended
mode,
a
port
transmits
only
LACP
data
units
(LACPDUs)
and
discards
all
other
traffic.
A
port
may
also
be
placed
in
suspended
mode
for
the
following
reasons:
When
LACP
is
configured
on
the
port
but
it
stops
receiving
LACPDUs
from
the
partner
switch.
When
the
port
has
a
different
LAG
ID
because
of
the
partner
switch
MAC
being
different.
For
example:
when
a
switch
is
connected
to
two
partners.
LAG
ID
can
be
configured
using
the
following
command:
LACP
provides
for
the
controlled
addition
and
removal
of
physical
links
for
the
link
aggregation.
LACP Modes
Each
port
in
the
NE2552E
can
have
one
of
the
following
LACP
modes.
off
(default)
The
user
can
configure
this
port
in
to
a
regular
static
LAG.
active
The
port
is
capable
of
forming
a
LACP
LAG.
This
port
sends
LACPDU
packets
to
partner
system
ports.
passive
The
port
is
capable
of
forming
a
LACP
LAG.
This
port
only
responds
to
the
LACPDU
packets
sent
from
a
LACP
active
port.
Each
active
LACP
port
transmits
LACP
data
units
(LACPDUs),
while
each
passive
LACP
port
listens
for
LACPDUs.
During
LACP
negotiation,
the
admin
key
is
exchanged.
The
LACP
LAG
is
enabled
as
long
as
the
information
matches
at
both
ends
of
the
link.
If
the
admin
key
value
changes
for
a
port
at
either
end
of
the
link,
that
port’s
association
with
the
LACP
LAG
is
lost.
If
a
LACP
LAG
member
port
is
connected
to
a
port
that
is
in
LACP
off
mode,
the
LACP
port
will
not
be
able
to
converge
and
the
link
goes
down.
When
the
system
is
initialized,
all
ports
are
by
default
in
LACP
off
mode
and
are
assigned
unique
admin
keys
.
To
make
a
group
of
ports
capable
of
being
aggregated,
you
assign
them
all
the
same
admin key
.
You
must
set
the
port’s
LACP
mode
to
active
to
activate
LACP
negotiation.
You
can
set
other
port’s
LACP
mode
to
passive,
to
reduce
the
amount
of
LACPDU
traffic
at
the
initial
LAG
‐
forming
stage.
NE2552E(config)#
portchannel
<53
‐
104>
lacp key
<adminkey
of
the
LAG>
Summary of Contents for ThinkSystem NE2552E
Page 27: ... Copyright Lenovo 2018 27 Part 1 Getting Started ...
Page 28: ...28 NE2552E Application Guide for ENOS 8 4 ...
Page 70: ...70 NE2552E Application Guide for ENOS 8 4 ...
Page 85: ... Copyright Lenovo 2018 85 Part 2 Securing the Switch ...
Page 86: ...86 NE2552E Application Guide for ENOS 8 4 ...
Page 112: ...112 NE2552E Application Guide for ENOS 8 4 ...
Page 134: ...134 NE2552E Application Guide for ENOS 8 4 ...
Page 154: ...154 NE2552E Application Guide for ENOS 8 4 ...
Page 194: ...194 NE2552E Application Guide for ENOS 8 4 ...
Page 218: ...218 NE2552E Application Guide for ENOS 8 4 ...
Page 234: ...234 NE2552E Application Guide for ENOS 8 4 ...
Page 238: ...238 NE2552E Application Guide for ENOS 8 4 ...
Page 239: ... Copyright Lenovo 2018 239 Part 4 Advanced Switching Features ...
Page 240: ...240 NE2552E Application Guide for ENOS 8 4 ...
Page 242: ...242 NE2552E Application Guide for ENOS 8 4 ...
Page 278: ...278 NE2552E Application Guide for ENOS 8 4 ...
Page 284: ...284 NE2552E Application Guide for ENOS 8 4 ...
Page 314: ...314 NE2552E Application Guide for ENOS 8 4 ...
Page 338: ...338 NE2552E Application Guide for ENOS 8 4 ...
Page 374: ...374 NE2552E Application Guide for ENOS 8 4 ...
Page 388: ...388 NE2552E Application Guide for ENOS 8 4 ...
Page 418: ...418 NE2552E Application Guide for ENOS 8 4 ...
Page 430: ...430 NE2552E Application Guide for ENOS 8 4 ...
Page 432: ...432 NE2552E Application Guide for ENOS 8 4 ...
Page 436: ...436 NE2552E Application Guide for ENOS 8 4 ...
Page 460: ...460 NE2552E Application Guide for ENOS 8 4 ...
Page 461: ... Copyright Lenovo 2018 461 Part 7 Network Management ...
Page 462: ...462 NE2552E Application Guide for ENOS 8 4 ...
Page 476: ...476 NE2552E Application Guide for ENOS 8 4 ...
Page 498: ...498 NE2552E Application Guide for ENOS 8 4 ...
Page 520: ...520 NE2552E Application Guide for ENOS 8 4 ...
Page 534: ...534 NE2552E Application Guide for ENOS 8 4 ...
Page 536: ...536 NE2552E Application Guide for ENOS 8 4 ...
Page 544: ...544 NE2552E Application Guide for ENOS 8 4 ...
Page 549: ... Copyright Lenovo 2018 549 Part 9 Appendices ...
Page 550: ...550 NE2552E Application Guide for ENOS 8 4 ...
Page 566: ...566 NE2552E Application Guide for ENOS 8 4 ...
Page 572: ...572 NE2552E Application Guide for ENOS 8 4 ...
Page 573: ......
Page 574: ...Part Number 01KN246 Printed in USA IP P N 01KN246 ...